<11006749 001>
Page 33 of 50
measured between: U1 (V) required U1
(Vpk)
U2 (V) required U2
(Vpk)
Neutral – T8 Pin 10 *
)
-- -- -- --
Line – T8 Pin 9 *
)
-- -- -- --
Neutral – T8 Pin 9 *
)
-- -- -- --
For equipment equipped with QDI panel
Line – plastic enclosure *
)
-- -- -- --
Neutral – plastic enclosure *
)
-- -- -- --
Line – SELV (earthed) 0.27 35 0.03 0.35
Neutral – SELV (earthed) 0.34 35 0.05 0.35
Line – CN3 Pin 1 0.02 35 0.02 0.35
Neutral – CN3 Pin 1 0.02 35 0.02 0.35
Line – CN3 Pin 2 0.02 35 0.02 0.35
Neutral – CN3 Pin 2 0.02 35 0.02 0.35
Line – T2 Pin 6, 7 *
)
-- -- -- --
Neutral – T2 Pin 6, 7 *
)
-- -- -- --
Line – T2 Pin 5 0.02 35 0.02 0.35
Neutral – T2 Pin 5 0.02 35 0.02 0.35
Line – T2 Pin 8 0.02 35 0.02 0.35
Neutral – T2 Pin 8 0.02 35 0.02 0.35
Note:
Test at 264Vac, 60Hz
The above test conducted after blocked opening test.
The above test location with symbol “
*
)
“
denoted that open-circuit voltage is below than 35V (peak)
or 60Vdc.
11.2 TABLE: summary of fault condition tests
P
Voltage (V) 0,9 or 1,1 times rated voltage .............. :
Rated voltage AC 264V —
Ambient temperature (
o
C) ...................................... :
See below —
Monitored point:
Under fault conditions specified below
∆T (K) Limit ∆T
(K)
Part Fault Test
Voltage
Test
Time
Input
current
Remark -- --
For equipment equipped with AUO panel
Commenti su questo manuale