Acer Altos R720 SeriesUser’s Guide

Pagina 3 - FCC notice

3 System upgrade90To install the SAS/SATA backplane board:1 Observe the ESD precautions and pre-installation instructions described on page 35.2 Remo

Pagina 4 - Laser compliance statement

91Configuring the integrated SAS hardware RAID componentsThe system supports hardware RAID through the SAS mid-plane and backplane board. The server p

Pagina 5 - Important safety instructions

3 System upgrade925 Store the activation key in an anti-static bag. 6 Observe the post-installation instructions described on page 36.To install the

Pagina 6

934 Gently pull the RAID cache upward to remove it from the slot (B). 5 Close the clips. 6 Replace the air baffles and CPU air duct. 7 Observe the pos

Pagina 7 - Contents

3 System upgrade94Removing and installing the RAID BBU To remove the RAID BBU:1 Observe the ESD precautions and pre-installation instructions describ

Pagina 8 - 5 Troubleshooting 133

958 Observe the post-installation instructions described on page 36.To install the RAID BBU1 Observe the ESD precautions and pre-installation instruct

Pagina 9 - Index 173

3 System upgrade966 Engage the hooks on the back of the battery into the matching chassis tabs, then slide it toward the power supply to lock into pl

Pagina 10

4 BIOS setup

Pagina 11 - 1 System tour

This chapter gives information about the system BIOS and discusses how to configure the system by changing the settings of the BIOS parameters.

Pagina 12

99BIOS setup BIOS setup is a hardware configuration program built into the system's Basic Input/Output System (BIOS). Since most systems are alre

Pagina 14 - PCI I/O

4 BIOS setup100Entering BIOS setupPower on the server to start the system POST process. During bootup, press F2 to enter the BIOS setup screen. Note:

Pagina 15 - I/O ports

101•Press F1 for General Help on using the BIOS setup.•Press F9 to load the default configuration.•Press F10 to save changes and close the BIOS setup.

Pagina 16 - 1 System tour

4 BIOS setup102Using the BIOS menusMainThe Main menu displays basic and important information about the system. These information are necessary for t

Pagina 17 - Front bezel

103Processor Specification of the processor currently installed in the server. Total Memory Indicates the size of the system memory.Quiet Boot When En

Pagina 18 - Front panel

4 BIOS setup104AdvancedThe Advanced menu contains parameter values that define how the system behaves on startup. Warning! Be cautious in setting par

Pagina 19

105ProcessorThe Processor submenu displays CPU settings such as type, actual speed, cache size and other CPU related settings. Parameter Description O

Pagina 20 - Front panel LED indicators

4 BIOS setup106Virtualization TechnologyEnables or disables the system to run multiple operating systems and applications in different partition. Di

Pagina 21

107Processor # InformationThe screen below appears when you select the Processor #1 or 2 Information menu.

Pagina 22

4 BIOS setup108MemoryThe Memory submenu displays the total amount of memory installed, the number of memory modules installed, and the current memory

Pagina 23 - Rear panel

109Configure Memory RAS and PerformanceThe screen below appears when you select the Configure Memory RAS and Performance menu. This submenu allows you

Pagina 24 - Rear panel LED indicators

The Acer Altos R720 is a 2U rack optimized server that features single or dual-core Intel Xeon processors, fully buffered DIMMs, integrated SAS RAID,

Pagina 25

4 BIOS setup110ATA ControllerThe ATA Controller submenu lets you define the parameter settings related to the hard disk(s). Thermal ThrottlingEnable

Pagina 26 - Internal components

111Onboard SATA ControllerEnables or disables the integrated Serial ATA controller. EnabledDisabledSATA Mode When set to Enhanced, it will enable all

Pagina 27 - System boards

4 BIOS setup112Mass Storage The Mass Storage submenu displays the status of the mass storage controller. Parameter Description OptionSAS Controll

Pagina 28

113Serial PortThe Serial Port submenu lets you define the parameter settings for the system’s serial port. Parameter Description OptionSerial A Enable

Pagina 29 - Backplane and mid-plane board

4 BIOS setup114USB ConfgurationThe USB Configuration submenu allows you specify settings for USB devices. Parameter Description OptionUSB Controller

Pagina 30 - Rear view

115Storage EmulationWhen set to Auto, USB mass storage devices with less than 530 MB will be emulated as a floppy and the remaining as hard drives. Th

Pagina 31 - SAS mid-plane board

4 BIOS setup116PCIThe PCI submenu lets you specify settings that are related to the onboard controllers. enable or disable the ROM scan of a device i

Pagina 32 - System diagnostic LEDs

117Onboard NIC ROMEnables or disables both channels of the embedded LAN. Note: If disabled, NIC1 and NIC2 cannot be used to boot the system. EnabledD

Pagina 33 - System jumpers

4 BIOS setup118System Acoustic and Performance ConfigurationThe System Acoustic and Performance Configuration submenu lets you set the system fan per

Pagina 34

119SecurityThe Security menu allows you to safeguard and protect the system from unauthorized use by setting up access passwords. Parameter Descriptio

Pagina 35 - 2 System setup

3Features summaryListed below are the system’s key features:Processor• Supports two dual-core Intel® Xeon™ processors 5000 sequence with 2 x 2 MB L2 c

Pagina 36

4 BIOS setup120To set a Administrator/User password1 Use the up/down keys to highlight a password parameter (Set Administrator Password or Set User P

Pagina 37 - Setting up the system

121Server Management The Server Management submenu lets you specify the appropriate settings for the system’s event handling function. The system even

Pagina 38 - Connecting peripherals

4 BIOS setup122Resume on AC Power LossDefines the mode of operation if a power loss occurs.When set to Stay Off, the system remains off after power s

Pagina 39 - Turning on the system

123Console RedirectionThe Console Redirection submenu lets you enable or disable the console redirection parameters for server management tasks over

Pagina 40 - Power-on problems

4 BIOS setup124System InformationThe System Information submenu displays basic information about the server unit.

Pagina 41 - Configuring the system OS

125Boot OptionsThe Boot Options menu allows you to set the BEV device priority during system bootup. It also displays information about the installed

Pagina 42 - Turning off the system

4 BIOS setup126BEV Device #The BEV Device # submenu lets you specify the preferred settings for system bootup. Parameter Description OptionBoot Time

Pagina 43 - 3 System upgrade

127CD-ROM Order Specifies the boot device priority sequence for available CD drives. Floppy Order Specifies the boot device priority sequence for avai

Pagina 44

4 BIOS setup128Boot ManagerThe Boot Manager menu lets you set the device priority during system bootup. The server will attempt to boot from the firs

Pagina 45 - Installation precautions

129Error ManagerThe Error Manager menu lets you view the system POST errors detected by the system.

Pagina 46

1 System tour4- 3.5-inch half-height tape driveSAS controller• LSI SAS 1068 3Gb/s SAS controller• Supports integrated SAS RAID• Supports RAID levels

Pagina 47 - Opening the server

4 BIOS setup130ExitThe Exit menu displays the various options to quit from the BIOS setup. Highlight any of the exit options then press Enter. Parame

Pagina 48 - To remove the front bezel:

131Restore User Default ValuesRestores previously saved user default values. Parameter Description

Pagina 49 - To install the front bezel:

4 BIOS setup132Upgrading the BIOSThe upgrade utility allows you to upgrade the BIOS in the flash memory. To prepare to upgrade the BIOS, you need to

Pagina 51 - To install the top cover:

This chapter provides possible solutions for specific problems. If you cannot correct the problem, contact your local Acer representative or authorize

Pagina 52 - To remove the CPU air duct:

135TroubleshootingThis chapter helps you identify and solve problems that might occur while you are using the system.For any issue, first ensure that

Pagina 53 - To install the CPU air duct:

5 Troubleshooting136First steps checklist• AC power available at the wall outlet?• Are the power supplies plugged in? Check the AC cable(s) on the ba

Pagina 54 - Removing the CPU air dam

137Hardware diagnostic testingThis section provides a more detailed approach to identifying a hardware problem and locating its source.Caution! Before

Pagina 55

5 Troubleshooting138Confirming loading of the OSOnce the system boots up, the operating system prompt appears on the screen. The prompt varies accord

Pagina 56

139Server boot does not complete POSTDo the following:• Make sure the CPU is properly seated. • Check the BIOS release notes to ensure the BIOS instal

Pagina 57

5Graphic interface•ATI® ES1000 video controller with 16MB DDR SDRAM Baseboard Management Controller• Integrated BMC• IPMI (Intelligent Platform Manage

Pagina 58 - To remove a HDD:

5 Troubleshooting140If you have installed one or more hard drives in the system, do the following:• Make sure the power and signal cables are connec

Pagina 59 - To install a HDD:

141Hard drives are not recognized.Do the following:• Make sure the disk controller is not disabled in the BIOS setup.• Make sure the drive is compatib

Pagina 60

5 Troubleshooting142Problems with the networkNetwork status indicator does not light.Do the following:• Check the cabling and network equipment to ma

Pagina 61

143• Network might be idle. Try accessing the server.Server hangs when the drivers are loaded.Change the PCI interrrupt settings. There is problem wit

Pagina 62

5 Troubleshooting144• Make sure the memory modules comply with the system requirements.• Make sure the memory modules have been populated according t

Pagina 63

145Check the following:• Is the power indicator lit? If not, see “Power indicator does not light.” on page 138 .• Have any of the fan motors stopped?

Pagina 64

5 Troubleshooting146Error beep codesBIOS POST error beep codesThe following table lists the POST error beep codes. Prior to system video initializati

Pagina 65

147Troubleshooting BIOS POST error beep codesThe following table lists the possible beep codes thay may occur while using the system and is followed b

Pagina 66 - Installing and removing a FDD

5 Troubleshooting148ARMC/3 module error beep codesIn addition to the beep codes above, additional beep codes are provided if an ARMC/3 module is inst

Pagina 67

149Diagnostic POST code LEDsDuring the system boot process, BIOS executes a number of platform configuration processes, each of which is assigned a sp

Pagina 68

1 System tour6Operating system and utilities• Operating system options:• Microsoft® Windows® Server 2003, x64 edition• Microsoft Windows Server 2003•

Pagina 69

5 Troubleshooting1500x13h OFF OFF G A SMM initializationChipset0x21h OFF OFF R G Initializing a chipset componentMemory0x22h OFF OFF A OFF Reading co

Pagina 70 - Installing a tape drive

151ATA / ATAPI / SATA0x5Ah G R G R Resetting PATA / SATA bus and all devices0x5Bh G R G A Reserved for ATASMBUS0x5Ch G A OFF R Resetting SMBUS0x5Dh G

Pagina 71

5 Troubleshooting1520x9Bh A OFF G A Enabling the mouseFixed Media0xB0h R OFF R R Resetting fixed media device0xB1h R OFF R A Disabling fixed media de

Pagina 72 - Installing a sixth HDD

1530xDB A R G A Trying boot device selection 0xDC A A OFF R Trying boot device selection 0xDE AAGR Trying boot device selection 0xDF AAGATrying boot d

Pagina 73

5 Troubleshooting1540xF8h A R R R Operating system has requested EFI to close boot services (Exit Boot Services has been called)0xF9h A R R A Operati

Pagina 74

Appendix A: Acer Altos R720rack installation guide

Pagina 75

This appendix shows you how to set up the Altos R720 server in a rack mount configuration.

Pagina 76 - 7 Add or remove PCI cards

157Setting up the system rackImportant! Observe the electrostatic discharge (ESD) precautions indicated on page 35 when perfoming the following proced

Pagina 77

Appendix A: Acer Altos R720 rack installation guide158• Elevated operating ambient temperature The maximum operating temperature of the system is 35

Pagina 78 - To install a PCI riser board:

159System rack installation The Altos R720 server system should be mounted into a rack. A tool-less rack rail and CMA (cable management arm) kit is av

Pagina 79 - To remove a PCI card:

7External and internal structureFront bezelThe front bezel provides an interface for system management via status LED indicators. The light pipes on t

Pagina 80 - To install a PCI card

Appendix A: Acer Altos R720 rack installation guide160Vertical mounting hole patternThe four vertical rails of the system rack contain mounting holes

Pagina 81

161Installing the system into the rackCaution! To minimize the chances of injuries, make sure that two or more people help in installing the server. T

Pagina 82 - Replacing a system fan

Appendix A: Acer Altos R720 rack installation guide162(3) Do the same thing to the other mounting rail.Caution! To avoid personal injury, care should

Pagina 83

1633 Install the mounting rails to the rack posts. (1) Determine the vertical position in the rack. Refer to “Vertical mounting hole pattern” on page

Pagina 84 - Upgrading the CPU

Appendix A: Acer Altos R720 rack installation guide164(6) Fully extend the mounting rails on the rack.

Pagina 85 - To install a CPU:

1654 Install the server into the rack.Caution! To avoid personal injury, care should be taken when pressing the inner rail release latches and sliding

Pagina 86

Appendix A: Acer Altos R720 rack installation guide1665 Attach the CMA (cable management arm) to the rear of the server.The CMA allows you to tie-wra

Pagina 87 - Upgrading the system memory

167(6) Connect the power, peripheral and networking cables into their appropriate ports. Refer to “Connecting peripherals” on page 28 for detailed ins

Pagina 88 - DDR2 module population order

Appendix A: Acer Altos R720 rack installation guide168

Pagina 89 - To remove DIMMs

Appendix B: SAS hardware RAID configuration

Pagina 90

1 System tour8Front panel * The dual purpose drive bay is covered by two filler panels. To configure the drive bay tosupport a sixth hot-plug SAS HD

Pagina 91

This appendix shows you how to create a RAID volume with integrated SAS hardware RAID.

Pagina 92

171Configuring the integrated SAS hardware RAID This section briefly shows how to create RAID with integrated SAS hardware RAID.Starting integrated SA

Pagina 93

Appendix B: SAS hardware RAID configuration1729 Click Yes to initialize the new logical drives. The logical drives will be listed.10 Click Home to go

Pagina 94 - To remove an ARMC/3 module:

173IndexAair bafflesinstalling 45removing 45ARMC/3 moduleinstalling 85removing 84BBIOS menusAdvanced 104ATA Controller 110Mass Stora

Pagina 95 - To install an ARMC/3 module:

174removing 52Llarge air baffleinstalling 47removing 46Mmemory 81reconfiguring 80NNIC moduleinstalling 86removing 84Oopening the

Pagina 96

175OS 6PCI I/O 4power supply 5processor 3SAS mid-plane board 4serial ATA port 4system fan 5system boards 17backplane 19SAS

Pagina 98

9Front panel control button functionsBelow table lists the functions of the front panel control buttons. Item FunctionNMI button Puts the server in a

Pagina 99

Changes may be made periodically to the information in this publication without obligation to notify any person of such revision or changes. Such cha

Pagina 100 - 3 System upgrade

1 System tour10Front panel LED indicatorsThe illustration below shows the LED indicators available on the control panel and hot-plug HDD. ItemLED in

Pagina 101

11CPower/Sleep indicator Green, off Power off System is not powered on. Green, on Power on System has power applied to it.Green, off S4/S5 System is

Pagina 102 - To remove the RAID cache:

1 System tour12D Status/fault indicator (cont.)Amber, blinking Non-critical condition• Non-critical temperature, voltage, or fan threshold crossing.•

Pagina 103 - To install the RAID cache:

13Rear panel 1 The system power can be configured to support non-redundant (1+0) configuration. 2 Reserved for remote management of server. This requ

Pagina 104 - To remove the RAID BBU:

1 System tour14Rear panel LED indicatorsThe illustration below shows the LED indicators located on the rear panel. ItemLED indicatorFunction/StatusC

Pagina 105 - To install the RAID BBU

15* For more information on how to troubleshoot during a system hang, refer to the Diagnostic POST Code table on page 149. C System ID indicatorID Blu

Pagina 106

1 System tour16Internal components Item Component Item ComponentA SAS/SATA backplane board F MainboardB Air baffles G Memory modules C Power dis

Pagina 107 - 4 BIOS setup

17System boardsMainboardThe mainboard becomes accessible once you open the system. It should look like the figure shown below.Item Description Item D

Pagina 108

1 System tour18C Diagnostic POST code indicatorsCC SATA 0 connectorD Full height riser slot DD SATA 1 connectorE Low profile riser slot EE SATA 2 con

Pagina 109 - BIOS setup

19* Reserved for remote management of server. This requires installation of an ARMC/3 module.Backplane and mid-plane boardSAS/SATA backplane boardFron

Pagina 110 - Entering BIOS setup

iiiNoticesFCC notice Class A equipmentThis device has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15

Pagina 111

1 System tour20Rear view Item Description Item DescriptionA Flex bay power cable connectorD Backplane power connectorB Flex bay data cable connector

Pagina 112 - Using the BIOS menus

21SAS mid-plane board Item Description Item DescriptionA Fan 1 power connector G Integrated SAS hardware RAID BBU (battery backup unit) connectorB Fa

Pagina 113

1 System tour22System diagnostic LEDs * For more information on how to troubleshoot during a system hang, refer to the Diagnostic POST code table on

Pagina 114 - Advanced

23System jumpers Jumper name Settings FunctionJ1D2Password clear1-2 (default)2-3Password enabledPassword disabled/clearedJ1D3Clear CMOS1-2 (default)2-

Pagina 115 - Processor

1 System tour24

Pagina 116

2 System setup

Pagina 117 - Processor # Information

This chapter gives you instructions on how to set up the system. Procedures on how to connect peripherals are also explained.

Pagina 118

27Setting up the systemPre-installation requirementsSelecting a siteBefore unpacking and installing the system, select a suitable site for the system

Pagina 119

2 System setup28Connecting peripheralsCaution! The server operates on 100-127/200-240 VAC only. Do not connect the system to an incorrect voltage sou

Pagina 120 - ATA Controller

29Turning on the systemAfter making sure that you have properly set up the system and connected all the required cables, you can now power on the syst

Pagina 121

ivCaution! Changes or modifications not expressly approved by the manufacturer could void the user’s authority, which is granted by the Federal Commun

Pagina 122 - Mass Storage

2 System setup30If the POST finds any problems, the system will emit a beep code followed by an error message displayed on the monitor. Aside from th

Pagina 123 - Serial Port

31Configuring the system OSThe Altos R720 comes with Acer EasyBUILDTM that allows you to conveniently install your choice of operating system. To star

Pagina 124 - USB Confguration

2 System setup32Turning off the systemThere are two ways by which you can turn off the server. These include:• If you are using a Windows OS on your

Pagina 125

3 System upgrade

Pagina 126

This chapter discusses the precautionary measures and installation procedures you need to know to upgrade the system.

Pagina 127

35Installation precautionsBefore you install any server component, we recommend that you read the following sections. These sections contain important

Pagina 128

3 System upgrade36Warning! Failure to properly turn off the server before you start installing components may cause serious damage. Do not attempt th

Pagina 129 - Security

37Opening the serverCaution! Before you proceed, make sure that you have turned off the system and all peripherals connected to it. Read the “Pre-inst

Pagina 130 - To remove the User password

3 System upgrade38Removing and installing the front bezelTo remove the front bezel:1 If the bezel is locked, unlock it. 2 Disconnect any cables atta

Pagina 131 - Server Management

39To install the front bezel:1 Line up the center notch on both ends of the bezel with the center guide on the rack handles. 2 Slide the front bezel o

Pagina 132

vImportant safety instructionsRead these instructions carefully. Save these instructions for future reference.1 Follow all warnings and instructions m

Pagina 133 - Console Redirection

3 System upgrade40Removing and installing the top coverTo remove the top cover:1 Observe the ESD precautions and pre-installation instructions descri

Pagina 134 - System Information

41To install the top cover:1 Observe the ESD precautions and pre-installation instructions described on page 35.2 Place the top cover on the chassis s

Pagina 135 - Boot Options

3 System upgrade42Removing and installing the CPU air ductCaution! Always operate your server with the CPU air duct installed to ensure reliable and

Pagina 136 - BEV Device #

43To install the CPU air duct:1 Observe the ESD precautions and pre-installation instructions described on page 35.2 Place the CPU air duct over the t

Pagina 137

3 System upgrade44Removing the CPU air damTo remove the CPU air dam:Important: Do not remove the CPU air dam if only one processor is installed. Do n

Pagina 138 - Boot Manager

45Removing and installing the air bafflesCaution! Always operate your server with both the air baffles installed to ensure reliable and continued ope

Pagina 139 - Error Manager

3 System upgrade46To remove the large air baffle:1 Observe the ESD precautions and pre-installation instructions described on page 35.2 Note how the

Pagina 140

47To install the large air baffle1 Observe the ESD precautions and pre-installation instructions described on page 35.2 Lower the air baffle into the

Pagina 141 - Parameter Description

3 System upgrade48Removing and installing storage devices The system supports 3.5-inch and 5.25-inch storage devices. The system comes pre-installed

Pagina 142 - Upgrading the BIOS

494 Pull out the lever and slide the carrier from the chassis (B). 5 Place the HDD carrier on a clean, static-free work surface. 6 If you are replacin

Pagina 143 - 5 Troubleshooting

vid If the product does not operate normally when the operating instructions are followed. Adjust only those controls that are covered by the operatin

Pagina 144

3 System upgrade506 Install a hard disk on the HDD carrier, then secure it with the four screws (A) that came with the HDD carrier (B). 7 With the le

Pagina 145 - Troubleshooting

51Removing and installing a slim-line optical driveNote: The slim-line optical drive is not hot-swappable. Before removing or replacing the drive, you

Pagina 146 - First steps checklist

3 System upgrade524 Remove the screw that secures the interposer board to the optical drive tray. 5 Pull the interposer board to remove it, then stor

Pagina 147 - Hardware diagnostic testing

539 Install the filler panel into the drive bay.If installing a new optical drive, see succeeding section. To install a slim-line optical drive:1 Obse

Pagina 148 - Confirming loading of the OS

3 System upgrade546 Install the new optical drive into the optical drive tray by aligning the two holes on the left edge of the optical device with t

Pagina 149

5511 For installing an optional USB floppy drive, note the location of the USB connector (C) on the backplane board and refer “To install a FDD in a c

Pagina 150 - ODD drive cannot read a disc

3 System upgrade56Installing and removing a FDDYou can choose to install a FDD into either the slim-line optical drive bay or the top, left-hand HDD

Pagina 151

573 Remove the slim-line optical drive. See “To remove a slim-line optical drive” section on page 51.4 If a drive carrier cover is installed, remove t

Pagina 152 - 5 Troubleshooting

3 System upgrade589 Secure the FDD into the carrier with the two screws that came with your diskette drive conversion kit. 10 Attach the slide rails

Pagina 153

5913 Observe the post-installation instructions described on page 36.To remove the FDD from the optical drive bay: 1 Observe the ESD precautions and p

Pagina 154

ContentsNotices iiiFCC notice iiiLaser compliance statement ivImportant safety instructions v1 System tour 1Features summary 3External and internal

Pagina 155

3 System upgrade606 Install an empty hot-plug HDD carrier or a filler panel into the HDD bay. If installing a new FDD, see “To install a FDD in a con

Pagina 156 - Error beep codes

613 Remove the empty HDD carrier from the sixth drive bay. See “To remove a HDD” section on page 48.4 Attach the tape drive to the tape drive carrier

Pagina 157

3 System upgrade625 Slide the tape drive assembly into the combined tape drive or sixth drive bay until the carrier clicks into place. 6 Plug the dat

Pagina 158

633 Remove the empty HDD carrier from the sixth drive bay. See “ To remove a HDD” section on page 48.4 Slide the sixth HDD bracket into the backplane

Pagina 159 - G=Green, R=Red, A=Amber

3 System upgrade64Note: Make sure the board seats securely into the plastic retainer at the bottom of the opening in the backplane board. 7 Install a

Pagina 160

65Removing and installing a PCI cardNote: The PCI riser assembly includes an intrusion switch that engages the system cover. The intrusion switch is p

Pagina 161

3 System upgrade665 Lift the riser assembly from the chassis (B). 6 Place the riser assembly on a clean, static-free work surface. 7 Add or remove PC

Pagina 162

67To install the PCI riser assembly:1 Observe the ESD precautions and pre-installation instructions described on page 35.2 Lower the PCI riser assembl

Pagina 163

3 System upgrade68To remove a PCI riser board1 Observe the ESD precautions and pre-installation instructions described on page 35.2 Remove the CPU ai

Pagina 164

693 Remove the PCI riser assembly from the server. See “To remove the PCI riser assembly” section on page 65.4 While holding the blue release lever in

Pagina 165 - Appendix A: Acer Altos R720

viiiRemoving and installing a slim-line optical drive 51Installing and removing a FDD 56Installing a tape drive 60Installing a sixth HDD 62Removing an

Pagina 166

3 System upgrade70Note: The install sequence for low profile PCI cards on the opposite side of the riser assembly is the same. 6 Pull up the card to

Pagina 167 - Setting up the system rack

715 When removing a full height PCI riser board, open the full length PCI card retention clip on the front of the riser assembly by rotating it 90 deg

Pagina 168

3 System upgrade72Replacing a system fan The system fans on the server can be individually replaced or hot-swapped in the event of failure. To provid

Pagina 169 - System rack installation

733 Grasp the defective fan and lift it up the fan bay. 4 Install the new fan by sliding the new fan into an empty fan socket. 5 Observe the post-inst

Pagina 170

3 System upgrade74Upgrading the CPUThe server supports two dual-core Intel Xeon processors 5000 sequence with 2 x 2 MB L2 cache and 1066 MHz or 1333

Pagina 171

754 Loosen the four screws on the heat sink. 5 Lift the heat sink to remove it. 6 Place the heat sink upside down on a flat surface.Note: Wipe off the

Pagina 172

3 System upgrade763 Push the socket retainer lever handle down and away from the socket to release it, then pull the lever to a fully open, upright p

Pagina 173

77Upgrading the system memoryAltos R720 supports eight DDR2 fully buffered DIMM slots. Each slot supports 512 MB, 1 GB, and 2GB DDR2-533/667 FBDIMM. T

Pagina 174

3 System upgrade78DDR2 module population orderTo install DIMMsCaution! Use extreme care when installing a DIMM. Applying too much pressure can damage

Pagina 175

796 Press the holding clips inward to lock the DIMM in place (D). Note: The DIMM slot is slotted to ensure proper installation. If you insert a DIMM b

Pagina 176

ixFirst steps checklist 136Hardware diagnostic testing 137Verifying proper operation of key system lights 137Specific problems and corrective actions

Pagina 177

3 System upgrade80Caution! Use extreme care when removing DIMMs. Too much pressure can damage the connector. Apply only enough pressure on the plasti

Pagina 178

81Installing and removing a power supplyThe server has two hot-swap power supply module bays on the rear panel that accept hot-swap redundant power su

Pagina 179 - RAID configuration

3 System upgrade82To install a power supply module1 If a filler panel is installed, press the release lever (A) and use the finger hole to remove the

Pagina 180

83To remove a power supply moduleCaution! Power supply hot-swap operations should be performed only if a failure occurs in the power supply. 1 If the

Pagina 181

3 System upgrade84Removing and installing an ARMC/3 moduleThe optional ARMC/3 module provides server management firmware and functionality to the sys

Pagina 182 - Assigning a hot spare disk

855 Pull up the module to remove it from the connector (B). 6 Observe the post-installation instructions described on page 36.To install an ARMC/3 mod

Pagina 183

3 System upgrade864 Attach the module to the ARMC/3 module connector on the mainboard and snap the standoff into the matching hole on the mainboard (

Pagina 184

87Removing and installing the SAS mid-plane boardTo remove the SAS mid-plane board:1 Observe the ESD precautions and pre-installation instructions des

Pagina 185

3 System upgrade88To install the SAS mid-plane board1 Observe the ESD precautions and pre-installation instructions described on page 35.2 Remove the

Pagina 186

89Removing and installing the SAS/SATA backplane boardTo remove the SAS/SATA backplane board:1 Observe the ESD precautions and pre-installation instru